Page 210 Chapter 10: Troubleshooting
Step 3 Inspect the station(s) which were operating at the
time of failure.
Step 4 Turn on the station using the MANUAL TEST
function, and observe the flow in GPM.
Step 5 Compare the measured flow rate with the station
limits as well as the satellite Main Line Limit and
verify proper operation. The Main Line Limit
should be larger than the total of all simultaneously
"On" stations.
Step 6 Upon resolution of problem, CLEAR all warnings at
the satellites.
Troubleshooting
The following flow charts offer methods of diagnosing and
correcting specific problems. Many of the resolutions refer to a
page or section in this manual to serve as additional steps in
solving the problem. The references are identified by chapter
and page number.
For further assistance please consult our Rain Master technical
support department at (805) 527-4498, Monday through Friday
during the hours of 8:00 AM to 5:00 PM Pacific Time.
Warning:
Before disconnecting ANY Evolution DX2 circuit
board, ensure that all power has been removed
from the system. Power can be removed by the
main power switch. Ensure that all cables have
been properly connec
ted.