Rain Master Irrigation Systems DX2 User Manual
Page 194 Chapter 10: Troubleshooting
021 - FM - Multiple Flow Sensor 1 Assignment
Figure 162: Warning 021-FM Multiple Flow Meter 1 Assign
This warning appears at the submaster whenever the Flow Max
feature has been incorrectly set up by the user. Using Flow Max,
it is possible to assign a device (in this case Flow Sensor 1) to
any of the Flow Max participants. If the user makes an error by
assigning the flow sensor to more than one satellite, this warning
will appear at the submaster. Devices must be installed at one
physical location (controller) only.
Action:
Step 1 Review the Flow Max device connection list at the
via the F4=REVIEW ALL selection. Look for two
or more occurrences of Flow Sensor 1 throughout
the Flow Max participants.
Step 2 Note the incorrect assignment and remove it from
the location(s), which are in error.
Example:
Assume a flow sensor physical connection at the
submaster (address 01-00) and an inadvertent
assignment of Flow Sensor 1 at participant address
01-02.
To remove the incorrect assignment, go to the
satellite address 01-02 (third controller on the
hardwire link) and delete the entry using the
Flow Max setup function.
Step 3 IMPORTANT:
Upon resolution of problem, CLEAR all warnings at
the satellites.
WARNING = MULTIPLE FM 1 06/14/96 11:45AM